| 概要 | Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries. |
|---|---|
| 公表日 | 2019年6月18日7:15 |
| 登録日 | 2021年1月26日13:12 |
| 最終更新日 | 2024年11月21日12:06 |
| CVSS3.0 : MEDIUM | |
| スコア | 6.5 |
|---|---|
| ベクター | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 低 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | 高 |
| 可用性への影響(A) | なし |
| CVSS2.0 : MEDIUM | |
| スコア | 4.0 |
|---|---|
| ベクター | AV:N/AC:L/Au:S/C:N/I:P/A:N |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 単一 |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | 低 |
| 可用性への影響(A) | なし |
| 全ての特権を取得 | いいえ |
| ユーザー権限を取得 | いいえ |
| その他の権限を取得 | いいえ |
| ユーザー操作が必要 | いいえ |
| 構成1 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ishekar:endoscope_camera_firmware:*:*:*:*:*:*:*:* | |||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ishekar:endoscope_camera:-:*:*:*:*:*:*:* | ||||
| タイトル | Shekar Endoscope における証明書・パスワードの管理に関する脆弱性 |
|---|---|
| 概要 | Shekar Endoscope には、証明書・パスワードの管理に関する脆弱性が存在します。 |
| 想定される影響 | 情報を改ざんされる可能性があります。 |
| 対策 | ベンダ情報および参考情報を参照して適切な対策を実施してください。 |
| 公表日 | 2017年7月1日0:00 |
| 登録日 | 2019年6月24日18:02 |
| 最終更新日 | 2019年6月24日18:02 |
| SHEKAR Technology CO.,Ltd |
| Shekar Endoscope ファームウェア |
| No | 変更内容 | 変更日 |
|---|---|---|
| 1 | [2019年06月24日] 掲載 |
2019年6月24日18:02 |