複数の ABB AC500 V2 製品におけるリソースの枯渇に関する脆弱性
| Title |
複数の ABB AC500 V2 製品におけるリソースの枯渇に関する脆弱性
|
| Summary |
複数の ABB AC500 V2 製品には、リソースの枯渇に関する脆弱性が存在します。
|
| Possible impacts |
サービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution |
ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date |
Aug. 26, 2020, midnight |
| Registration Date |
Nov. 17, 2021, 4:28 p.m. |
| Last Update |
Nov. 17, 2021, 4:28 p.m. |
|
CVSS3.0 : 重要
|
| Score |
7.5
|
| Vector |
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
|
CVSS2.0 : 警告
|
| Score |
5
|
| Vector |
AV:N/AC:L/Au:N/C:N/I:N/A:P |
Affected System
| ABB |
|
PM554
|
|
PM556
|
|
PM564
|
|
PM566
|
|
PM572
|
|
PM573
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2021年11月17日] 掲載 |
Nov. 17, 2021, 4:28 p.m. |
NVD Vulnerability Information
CVE-2020-24686
| Summary |
The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.
|
| Publication Date |
Feb. 27, 2021, 1:15 a.m. |
| Registration Date |
Feb. 27, 2021, 10:01 a.m. |
| Last Update |
Nov. 21, 2024, 2:15 p.m. |
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm554_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm554:-:*:*:*:*:*:*:* |
| Configuration2 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm556_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm556:-:*:*:*:*:*:*:* |
| Configuration3 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm564_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm564:-:*:*:*:*:*:*:* |
| Configuration4 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm566_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm566:-:*:*:*:*:*:*:* |
| Configuration5 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm572_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm572:-:*:*:*:*:*:*:* |
| Configuration6 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:abb:pm573_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:abb:pm573:-:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List