CVE-2017-11579
| Summary |
In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.
|
| Publication Date |
July 3, 2019, 6:15 a.m. |
| Registration Date |
Jan. 26, 2021, 1:13 p.m. |
| Last Update |
Nov. 21, 2024, 12:08 p.m. |
|
CVSS3.0 : HIGH
|
| スコア |
7.1
|
| Vector |
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N |
| 攻撃元区分(AV) |
隣接 |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃に必要な特権レベル(PR) |
不要 |
| 利用者の関与(UI) |
不要 |
| 影響の想定範囲(S) |
変更なし |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
低 |
| 可用性への影響(A) |
なし |
|
CVSS2.0 : MEDIUM
|
| Score |
4.8
|
| Vector |
AV:A/AC:L/Au:N/C:P/I:P/A:N |
| 攻撃元区分(AV) |
隣接 |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
不要 |
| 機密性への影響(C) |
低 |
| 完全性への影響(I) |
低 |
| 可用性への影響(A) |
なし |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:blipcare:wi-fi_blood_pressure_monitor_firmware:*:*:*:*:*:*:*:* |
|
bp700_10.1 |
|
|
| execution environment |
| 1 |
cpe:2.3:h:blipcare:wi-fi_blood_pressure_monitor:-:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
Blipcare Wireless Blood pressure monitor におけるセキュリティ機能に関する脆弱性
| Title |
Blipcare Wireless Blood pressure monitor におけるセキュリティ機能に関する脆弱性
|
| Summary |
Blipcare Wireless Blood pressure monitor には、セキュリティ機能に関する脆弱性が存在します。
|
| Possible impacts |
情報を取得される、および情報を改ざんされる可能性があります。 |
| Solution |
ベンダ情報および参考情報を参照して適切な対策を実施してください。 |
| Publication Date |
July 23, 2017, midnight |
| Registration Date |
July 17, 2019, 2:03 p.m. |
| Last Update |
July 17, 2019, 2:03 p.m. |
Affected System
| Blipcare |
|
Wifi blood pressure monitor ファームウェア
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2019年07月17日] 掲載 |
July 17, 2019, 2:03 p.m. |