CVE-2019-18238
Summary

In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.

Publication Date Feb. 27, 2020, 7:15 a.m.
Registration Date Jan. 26, 2021, 11:40 a.m.
Last Update Nov. 21, 2024, 1:32 p.m.
CVSS3.1 : HIGH
スコア 7.5
Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃に必要な特権レベル(PR) 不要
利用者の関与(UI) 不要
影響の想定範囲(S) 変更なし
機密性への影響(C)
完全性への影響(I) なし
可用性への影響(A) なし
CVSS2.0 : MEDIUM
Score 5.0
Vector AV:N/AC:L/Au:N/C:P/I:N/A:N
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃前の認証要否(Au) 不要
機密性への影響(C)
完全性への影響(I) なし
可用性への影響(A) なし
Get all privileges. いいえ
Get user privileges いいえ
Get other privileges いいえ
User operation required いいえ
Affected software configurations
Configuration1 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512:-:*:*:*:*:*:*:*
Configuration2 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-t:-:*:*:*:*:*:*:*
Configuration3 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-hspa_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-hspa:-:*:*:*:*:*:*:*
Configuration4 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-hspa-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-hspa-t:-:*:*:*:*:*:*:*
Configuration5 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-eu_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-eu:-:*:*:*:*:*:*:*
Configuration6 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-eu-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-eu-t:-:*:*:*:*:*:*:*
Configuration7 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-us_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-us:-:*:*:*:*:*:*:*
Configuration8 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-us-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-us-t:-:*:*:*:*:*:*:*
Configuration9 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-jp_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-jp:-:*:*:*:*:*:*:*
Configuration10 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2512-wl1-jp-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2512-wl1-jp-t:-:*:*:*:*:*:*:*
Configuration11 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542:-:*:*:*:*:*:*:*
Configuration12 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-t:-:*:*:*:*:*:*:*
Configuration13 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-hspa_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-hspa:-:*:*:*:*:*:*:*
Configuration14 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-hspa-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-hspa-t:-:*:*:*:*:*:*:*
Configuration15 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-eu_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-eu:-:*:*:*:*:*:*:*
Configuration16 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-eu-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-eu-t:-:*:*:*:*:*:*:*
Configuration17 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-us_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-us:-:*:*:*:*:*:*:*
Configuration18 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-us-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-us-t:-:*:*:*:*:*:*:*
Configuration19 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-jp_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-jp:-:*:*:*:*:*:*:*
Configuration20 or higher or less more than less than
cpe:2.3:o:moxa:iologik_2542-wl1-jp-t_firmware:*:*:*:*:*:*:*:* 3.0
execution environment
1 cpe:2.3:h:moxa:iologik_2542-wl1-jp-t:-:*:*:*:*:*:*:*
Related information, measures and tools
Common Vulnerabilities List

JVN Vulnerability Information
複数の Moxa ioLogik 製品における重要な情報の平文保存に関する脆弱性
Title 複数の Moxa ioLogik 製品における重要な情報の平文保存に関する脆弱性
Summary

複数の Moxa ioLogik 製品には、重要な情報の平文保存に関する脆弱性が存在します。

Possible impacts 情報を取得される可能性があります。
Solution

ベンダ情報および参考情報を参照して適切な対策を実施してください。

Publication Date Oct. 22, 2019, midnight
Registration Date March 13, 2020, 11:06 a.m.
Last Update March 13, 2020, 11:06 a.m.
Affected System
Moxa Inc.
ioLogik 2512 HSPA ファームウェア 
ioLogik 2512 HSPA-T ファームウェア 
ioLogik 2512 T ファームウェア 
ioLogik 2512 WL1-EU ファームウェア 
ioLogik 2512 ファームウェア 
ioLogik 2542 HSPA ファームウェア 
ioLogik 2542 HSPA-T ファームウェア 
ioLogik 2542 T ファームウェア 
ioLogik 2542 WL1-EU ファームウェア 
ioLogik 2542 ファームウェア 
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
No Changed Details Date of change
1 [2020年03月13日]
  掲載
March 13, 2020, 11:06 a.m.