CVE-2019-18336
| Summary |
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
|
| Publication Date |
March 11, 2020, 5:15 a.m. |
| Registration Date |
Jan. 26, 2021, 11:40 a.m. |
| Last Update |
Nov. 21, 2024, 1:33 p.m. |
|
CVSS3.1 : HIGH
|
| スコア |
7.5
|
| Vector |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 攻撃元区分(AV) |
ネットワーク |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃に必要な特権レベル(PR) |
不要 |
| 利用者の関与(UI) |
不要 |
| 影響の想定範囲(S) |
変更なし |
| 機密性への影響(C) |
なし |
| 完全性への影響(I) |
なし |
| 可用性への影響(A) |
高 |
|
CVSS2.0 : HIGH
|
| Score |
7.8
|
| Vector |
AV:N/AC:L/Au:N/C:N/I:N/A:C |
| 攻撃元区分(AV) |
ネットワーク |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
不要 |
| 機密性への影響(C) |
なし |
| 完全性への影響(I) |
なし |
| 可用性への影響(A) |
高 |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:* |
| Configuration2 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:* |
| Configuration3 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:* |
| Configuration4 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:* |
| Configuration5 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:* |
| Configuration6 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:* |
| Configuration7 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:* |
| Configuration8 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:* |
| Configuration9 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:* |
|
|
|
3.3.17 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:* |
| Configuration10 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:* |
|
|
|
4.8.6 |
| Configuration11 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:* |
|
|
|
4.94 |
| Configuration12 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:* |
|
|
|
1.1.8 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:* |
| Configuration13 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:* |
|
|
|
1.1.1 |
| execution environment |
| 1 |
cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
SIMATIC S7-300n および SINUMERIK 840D sl におけるリソースの枯渇に関する脆弱性
| Title |
SIMATIC S7-300n および SINUMERIK 840D sl におけるリソースの枯渇に関する脆弱性
|
| Summary |
SIMATIC S7-300n および SINUMERIK 840D sl には、リソースの枯渇に関する脆弱性が存在します。
|
| Possible impacts |
サービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution |
ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date |
Oct. 23, 2019, midnight |
| Registration Date |
March 23, 2020, 3:19 p.m. |
| Last Update |
March 27, 2020, 2:05 p.m. |
Affected System
| シーメンス |
|
SIMATIC S7-300 CPU 312 IFM ファームウェア
|
|
SIMATIC S7-300 CPU 313 ファームウェア
|
|
SIMATIC S7-300 CPU 314 IFM ファームウェア
|
|
SIMATIC S7-300 CPU 314 ファームウェア
|
|
SIMATIC S7-300 CPU 315 ファームウェア
|
|
SIMATIC S7-300 CPU 315-2 DP ファームウェア
|
|
SIMATIC S7-300 CPU 316-2 DP ファームウェア
|
|
SIMATIC S7-300 CPU 318-2 DP ファームウェア
|
|
SIMATIC S7-300 CPU ファームウェア
|
|
SINUMERIK 840D SL
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2020年03月23日] 掲載 |
March 23, 2020, 3:19 p.m. |
| 2 |
[2020年03月27日] 参考情報:ICS-CERT ADVISORY (ICSA-20-070-02) を追加 |
March 27, 2020, 11:04 a.m. |