| Summary | Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. |
|---|---|
| Publication Date | May 20, 2020, 12:15 p.m. |
| Registration Date | Jan. 26, 2021, 11:51 a.m. |
| Last Update | Nov. 21, 2024, 1:59 p.m. |
| CVSS3.1 : HIGH | |
| スコア | 8.2 |
|---|---|
| Vector | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H |
| 攻撃元区分(AV) | 隣接 |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更あり |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | 低 |
| 可用性への影響(A) | 高 |
| CVSS2.0 : MEDIUM | |
| Score | 4.8 |
|---|---|
| Vector | AV:A/AC:L/Au:N/C:N/I:P/A:P |
| 攻撃元区分(AV) | 隣接 |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | 低 |
| 可用性への影響(A) | 低 |
| Get all privileges. | いいえ |
| Get user privileges | いいえ |
| Get other privileges | いいえ |
| User operation required | いいえ |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:a:rockwellautomation:eds_subsystem:*:*:*:*:*:*:*:* | 28.0.1 | ||||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:a:rockwellautomation:rsnetworx:*:*:*:*:*:*:*:* | 28.00.00 | ||||
| cpe:2.3:a:rockwellautomation:rslinx:*:*:*:*:classic:*:*:* | 4.11.00 | ||||
| cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.10.00:*:*:*:*:*:*:* | |||||
| cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.11.00:*:*:*:*:*:*:* | |||||
| cpe:2.3:a:rockwellautomation:rslinx_enterprise:6.00.00:*:*:*:*:*:*:* | |||||
| cpe:2.3:a:rockwellautomation:studio_5000_logix_designer:*:*:*:*:*:*:*:* | 32.0 | ||||