| Summary | A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. |
|---|---|
| Publication Date | April 23, 2021, 6:15 a.m. |
| Registration Date | April 23, 2021, 10:04 a.m. |
| Last Update | Nov. 21, 2024, 2:21 p.m. |
| CVSS3.1 : MEDIUM | |
| スコア | 6.5 |
|---|---|
| Vector | CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 高 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | 低 |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 高 |
| CVSS2.0 : MEDIUM | |
| Score | 5.8 |
|---|---|
| Vector | AV:N/AC:M/Au:N/C:P/I:N/A:P |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 中 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | 低 |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 低 |
| Get all privileges. | いいえ |
| Get user privileges | いいえ |
| Get other privileges | いいえ |
| User operation required | いいえ |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:* | 0.5.0.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:* | ||||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:* | 2017.02.3 | ||||
| cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:* | 4.1.0 | ||||
| Title | 複数のシーメンス製品における境界外読み取りに関する脆弱性 |
|---|---|
| Summary | 複数のシーメンス製品には、境界外読み取りに関する脆弱性が存在します。 |
| Possible impacts | 情報を取得される、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution | ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date | Oct. 26, 2020, midnight |
| Registration Date | Dec. 27, 2021, 5:57 p.m. |
| Last Update | Dec. 27, 2021, 5:57 p.m. |
| シーメンス |
| Capital VSTAR |
| Nucleus 4 |
| Nucleus NET |
| Nucleus ReadyStart V3 2017/02/3 より前 |
| Nucleus ReadyStart V4 4.1.0 未満 |
| Nucleus Source Code |
| SIMOTICS CONNECT 400 ファームウェア 0.5.0.0 未満 |