CVE-2021-21557
| Summary |
Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of service, arbitrary code execution, or information disclosure in System Management Mode.
|
| Publication Date |
June 15, 2021, 4:15 a.m. |
| Registration Date |
June 15, 2021, 10 a.m. |
| Last Update |
Nov. 21, 2024, 2:48 p.m. |
|
CVSS3.1 : MEDIUM
|
| スコア |
6.7
|
| Vector |
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H |
| 攻撃元区分(AV) |
ローカル |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃に必要な特権レベル(PR) |
高 |
| 利用者の関与(UI) |
不要 |
| 影響の想定範囲(S) |
変更なし |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
高 |
| 可用性への影響(A) |
高 |
|
CVSS2.0 : HIGH
|
| Score |
7.2
|
| Vector |
AV:L/AC:L/Au:N/C:C/I:C/A:C |
| 攻撃元区分(AV) |
ローカル |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
不要 |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
高 |
| 可用性への影響(A) |
高 |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r640_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r640:-:*:*:*:*:*:*:* |
| Configuration2 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r740_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r740:-:*:*:*:*:*:*:* |
| Configuration3 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r740xd_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r740xd:-:*:*:*:*:*:*:* |
| Configuration4 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r940_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r940:-:*:*:*:*:*:*:* |
| Configuration5 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r540_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r540:-:*:*:*:*:*:*:* |
| Configuration6 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r440_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r440:-:*:*:*:*:*:*:* |
| Configuration7 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_t440_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_t440:-:*:*:*:*:*:*:* |
| Configuration8 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_xr2_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_xr2:-:*:*:*:*:*:*:* |
| Configuration9 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r740xd2_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r740xd2:-:*:*:*:*:*:*:* |
| Configuration10 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r840_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r840:-:*:*:*:*:*:*:* |
| Configuration11 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r940xa_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r940xa:-:*:*:*:*:*:*:* |
| Configuration12 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_t640_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_t640:-:*:*:*:*:*:*:* |
| Configuration13 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_c6420_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_c6420:-:*:*:*:*:*:*:* |
| Configuration14 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_fc640_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_fc640:-:*:*:*:*:*:*:* |
| Configuration15 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_m640_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_m640:-:*:*:*:*:*:*:* |
| Configuration16 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_m640p_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_m640p:-:*:*:*:*:*:*:* |
| Configuration17 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_mx740c_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_mx740c:-:*:*:*:*:*:*:* |
| Configuration18 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_mx840c_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_mx840c:-:*:*:*:*:*:*:* |
| Configuration19 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_c4140_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.11.2 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_c4140:-:*:*:*:*:*:*:* |
| Configuration20 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_t140_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.5.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_t140:-:*:*:*:*:*:*:* |
| Configuration21 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_t340_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.5.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_t340:-:*:*:*:*:*:*:* |
| Configuration22 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r240_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.5.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r240:-:*:*:*:*:*:*:* |
| Configuration23 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r340_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.5.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r340:-:*:*:*:*:*:*:* |
| Configuration24 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r6415_firmware:*:*:*:*:*:*:*:* |
|
|
|
1.16.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r6415:-:*:*:*:*:*:*:* |
| Configuration25 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r7415_firmware:*:*:*:*:*:*:*:* |
|
|
|
1.16.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r7415:-:*:*:*:*:*:*:* |
| Configuration26 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r7425_firmware:*:*:*:*:*:*:*:* |
|
|
|
1.16.1 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r7425:-:*:*:*:*:*:*:* |
| Configuration27 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r6515_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.2.4 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r6515:-:*:*:*:*:*:*:* |
| Configuration28 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r7515_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.2.4 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r7515:-:*:*:*:*:*:*:* |
| Configuration29 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r6525_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.2.5 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r6525:-:*:*:*:*:*:*:* |
| Configuration30 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_r7525_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.2.5 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_r7525:-:*:*:*:*:*:*:* |
| Configuration31 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dell:poweredge_c6525_firmware:*:*:*:*:*:*:*:* |
|
|
|
2.2.4 |
| execution environment |
| 1 |
cpe:2.3:h:dell:poweredge_c6525:-:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
Dell PowerEdge Server BIOS および一部の Dell Precision Rack BIOS におけるバッファエラーの脆弱性
| Title |
Dell PowerEdge Server BIOS および一部の Dell Precision Rack BIOS におけるバッファエラーの脆弱性
|
| Summary |
Dell PowerEdge Server BIOS および一部の Dell Precision Rack BIOS には、バッファエラーの脆弱性が存在します。
|
| Possible impacts |
情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution |
ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date |
June 8, 2021, midnight |
| Registration Date |
March 11, 2022, 11:41 a.m. |
| Last Update |
March 11, 2022, 11:41 a.m. |
Affected System
| デル |
|
Dell PowerEdge R440 ファームウェア
|
|
Dell PowerEdge R540 ファームウェア
|
|
Dell PowerEdge R640 ファームウェア
|
|
Dell PowerEdge R740 ファームウェア
|
|
Dell PowerEdge R740XD ファームウェア
|
|
Dell PowerEdge R740XD2 ファームウェア
|
|
Dell PowerEdge R840 ファームウェア
|
|
Dell PowerEdge R940 ファームウェア
|
|
Dell PowerEdge T440 ファームウェア
|
|
Dell PowerEdge XR2 ファームウェア
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2022年03月11日] 掲載 |
March 11, 2022, 11:41 a.m. |