| Summary | A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. |
|---|---|
| Publication Date | May 12, 2021, 11:15 p.m. |
| Registration Date | May 13, 2021, 10 a.m. |
| Last Update | Nov. 21, 2024, 2:55 p.m. |
| CVSS3.1 : HIGH | |
| スコア | 7.5 |
|---|---|
| Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 高 |
| CVSS2.0 : MEDIUM | |
| Score | 5.0 |
|---|---|
| Vector | AV:N/AC:L/Au:N/C:N/I:N/A:P |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 低 |
| Get all privileges. | いいえ |
| Get user privileges | いいえ |
| Get other privileges | いいえ |
| User operation required | いいえ |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\":-:*:*:*:*:*:*:* | ||||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:*:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\":-:*:*:*:*:*:*:* | ||||
| Configuration3 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\":-:*:*:*:*:*:*:* | ||||
| Configuration4 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\":-:*:*:*:*:*:*:* | ||||
| Configuration5 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:* | ||||
| Configuration6 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:* | ||||
| Configuration7 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:* | ||||
| Configuration8 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:* | ||||
| Configuration9 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* | 16 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:* | ||||
| Configuration10 | or higher | or less | more than | less than | |
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* | 16 | ||||
| Configuration11 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\":-:*:*:*:*:*:*:* | ||||
| Configuration12 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\":-:*:*:*:*:*:*:* | ||||
| Configuration13 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\":-:*:*:*:*:*:*:* | ||||
| Configuration14 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\":-:*:*:*:*:*:*:* | ||||
| Configuration15 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:* | ||||
| Configuration16 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:* | ||||
| Configuration17 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:* | ||||
| Configuration18 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:* | ||||
| Configuration19 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:* | ||||
| Configuration20 | or higher | or less | more than | less than | |
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* | 15.1 | ||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:* | |||||
| cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:* | |||||
| Title | 複数のシーメンス製品におけるバッファエラーの脆弱性 |
|---|---|
| Summary | 複数のシーメンス製品には、バッファエラーの脆弱性が存在します。 |
| Possible impacts | サービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution | ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date | May 11, 2021, midnight |
| Registration Date | Jan. 26, 2022, 4:30 p.m. |
| Last Update | Jan. 26, 2022, 4:30 p.m. |
| シーメンス |
| SIMATIC HMI Comfort Outdoor Panels 15" ファームウェア V16 Update 4 未満 |
| SIMATIC HMI Comfort Outdoor Panels 7" ファームウェア V16 Update 4 未満 |
| SIMATIC HMI Comfort Panels 22" ファームウェア V16 Update 4 未満 |
| SIMATIC HMI Comfort Panels 4" ファームウェア V16 Update 4 未満 |
| SIMATIC HMI KTP Mobile Panels KTP400F ファームウェア V16 Update 4 未満 |
| SIMATIC HMI KTP Mobile Panels KTP700 ファームウェア V16 Update 4 未満 |
| SIMATIC HMI KTP Mobile Panels KTP700F ファームウェア V16 Update 4 未満 |
| SIMATIC HMI KTP Mobile Panels KTP900 ファームウェア V16 Update 4 未満 |
| SIMATIC HMI KTP Mobile Panels KTP900F ファームウェア V16 Update 4 未満 |
| SIMATIC WinCC Runtime Advanced V16 Update 4 未満 |
| No | Changed Details | Date of change |
|---|---|---|
| 1 | [2022年01月26日] 掲載 |
Jan. 26, 2022, 4:30 p.m. |