NVD Vulnerability Detail
Search Exploit, PoC
CVE-2021-25667
Summary

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.

Publication Date March 16, 2021, 2:15 a.m.
Registration Date March 16, 2021, 10:02 a.m.
Last Update Nov. 21, 2024, 2:55 p.m.
CVSS3.1 : HIGH
スコア 8.8
Vector CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
攻撃元区分(AV) 隣接
攻撃条件の複雑さ(AC)
攻撃に必要な特権レベル(PR) 不要
利用者の関与(UI) 不要
影響の想定範囲(S) 変更なし
機密性への影響(C)
完全性への影響(I)
可用性への影響(A)
CVSS2.0 : MEDIUM
Score 5.8
Vector AV:A/AC:L/Au:N/C:P/I:P/A:P
攻撃元区分(AV) 隣接
攻撃条件の複雑さ(AC)
攻撃前の認証要否(Au) 不要
機密性への影響(C)
完全性への影響(I)
可用性への影響(A)
Get all privileges. いいえ
Get user privileges いいえ
Get other privileges いいえ
User operation required いいえ
Affected software configurations
Configuration1 or higher or less more than less than
cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:* 4.3 6.4
execution environment
1 cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*
Configuration2 or higher or less more than less than
cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:* 4.3 6.4
execution environment
1 cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*
Configuration3 or higher or less more than less than
cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:* 4.3 6.4
execution environment
1 cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*
Configuration4 or higher or less more than less than
cpe:2.3:o:siemens:scalance_x300wg_firmware:*:*:*:*:*:*:*:* 4.1
execution environment
1 cpe:2.3:h:siemens:scalance_x300wg:-:*:*:*:*:*:*:*
Configuration5 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:* 6.2
execution environment
1 cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*
Configuration6 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:* 6.2
execution environment
1 cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*
Configuration7 or higher or less more than less than
cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:* 2.0
cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:* 2.1 2.1.3
execution environment
1 cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*
Configuration8 or higher or less more than less than
cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:* 2.0
cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:* 2.1 2.1.3
execution environment
1 cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*
Configuration9 or higher or less more than less than
cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:* 2.0
cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:* 2.1 2.1.3
execution environment
1 cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*
Configuration10 or higher or less more than less than
cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:* 2.0
cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:* 2.1 2.1.3
execution environment
1 cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*
Configuration11 or higher or less more than less than
cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:* 2.0
cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:* 2.1 2.1.3
execution environment
1 cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*
Configuration12 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:* 4.1
execution environment
1 cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*
Configuration13 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:* 4.1
execution environment
1 cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*
Configuration14 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:* 4.1
execution environment
1 cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*
Configuration15 or higher or less more than less than
cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:* 4.1
execution environment
1 cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*
Related information, measures and tools
Common Vulnerabilities List

JVN Vulnerability Information
複数の Siemens 製品における境界外書き込みに関する脆弱性
Title 複数の Siemens 製品における境界外書き込みに関する脆弱性
Summary

複数の Siemens 製品には、境界外書き込みに関する脆弱性が存在します。

Possible impacts 情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。
Solution

ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。

Publication Date March 9, 2021, midnight
Registration Date Nov. 22, 2021, 6:03 p.m.
Last Update Nov. 22, 2021, 6:03 p.m.
Affected System
シーメンス
RUGGEDCOM RM1224 ファームウェア 4.3 以上 6.4 未満
SCALANCE M-800 ファームウェア 4.3 以上 6.4 未満
SCALANCE S615 ファームウェア 4.3 以上 6.4 未満
SCALANCE SC-622-2C ファームウェア 2.0以上 2.1.3 未満
SCALANCE SC-632-2C ファームウェア 2.0以上 2.1.3 未満
SCALANCE SC-636-2C ファームウェア 2.0以上 2.1.3 未満
SCALANCE SC-642-2C ファームウェア 2.0以上 2.1.3 未満
SCALANCE SC-646-2C ファームウェア 2.0以上 2.1.3 未満
SCALANCE XM400 ファームウェア 6.2 未満
SCALANCE XR500 ファームウェア 6.2 未満
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
No Changed Details Date of change
1 [2021年11月22日]
  掲載
Nov. 22, 2021, 6:03 p.m.