NVD Vulnerability Detail
Search Exploit, PoC
CVE-2021-27385
Summary

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.

Publication Date May 12, 2021, 11:15 p.m.
Registration Date May 13, 2021, 10 a.m.
Last Update Nov. 21, 2024, 2:57 p.m.
CVSS3.1 : HIGH
スコア 7.5
Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃に必要な特権レベル(PR) 不要
利用者の関与(UI) 不要
影響の想定範囲(S) 変更なし
機密性への影響(C) なし
完全性への影響(I) なし
可用性への影響(A)
CVSS2.0 : MEDIUM
Score 5.0
Vector AV:N/AC:L/Au:N/C:N/I:N/A:P
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃前の認証要否(Au) 不要
機密性への影響(C) なし
完全性への影響(I) なし
可用性への影響(A)
Get all privileges. いいえ
Get user privileges いいえ
Get other privileges いいえ
User operation required いいえ
Affected software configurations
Configuration1 or higher or less more than less than
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* 16
Configuration2 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*
Configuration3 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*
Configuration4 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*
Configuration5 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*
Configuration6 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*
Configuration7 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*
Configuration8 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*
Configuration9 or higher or less more than less than
cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*
Configuration10 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\":-:*:*:*:*:*:*:*
Configuration11 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\":-:*:*:*:*:*:*:*
Configuration12 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\":-:*:*:*:*:*:*:*
Configuration13 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\":-:*:*:*:*:*:*:*
Configuration14 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
Configuration15 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
Configuration16 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
Configuration17 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
Configuration18 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* 16
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
Configuration19 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\"_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\":-:*:*:*:*:*:*:*
Configuration20 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\"_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\":-:*:*:*:*:*:*:*
Configuration21 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\"_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\":-:*:*:*:*:*:*:*
Configuration22 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\"_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\":-:*:*:*:*:*:*:*
Configuration23 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*
Configuration24 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*
Configuration25 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*
Configuration26 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*
Configuration27 or higher or less more than less than
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:* 15.1
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*
execution environment
1 cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*
Configuration28 or higher or less more than less than
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:* 15.1
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*
cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*
Related information, measures and tools
Common Vulnerabilities List

JVN Vulnerability Information
複数のシーメンス製品におけるリソースの枯渇に関する脆弱性
Title 複数のシーメンス製品におけるリソースの枯渇に関する脆弱性
Summary

複数のシーメンス製品には、リソースの枯渇に関する脆弱性が存在します。

Possible impacts サービス運用妨害 (DoS) 状態にされる可能性があります。
Solution

ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。

Publication Date May 11, 2021, midnight
Registration Date Jan. 26, 2022, 4:30 p.m.
Last Update Jan. 26, 2022, 4:30 p.m.
Affected System
シーメンス
SIMATIC HMI Comfort Outdoor Panels 7" ファームウェア 
SIMATIC WinCC Runtime Advanced 
SINAMICS GH150 ファームウェア 
SINAMICS GL150 ファームウェア 
SINAMICS GM150 ファームウェア 
SINAMICS SH150 ファームウェア 
SINAMICS SL150 ファームウェア 
SINAMICS SM120 ファームウェア 
SINAMICS SM150 ファームウェア 
SINAMICS SM150i ファームウェア 
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
No Changed Details Date of change
1 [2022年01月26日]
  掲載
Jan. 26, 2022, 4:30 p.m.