| Summary | An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses. |
|---|---|
| Publication Date | Feb. 3, 2022, 11:15 a.m. |
| Registration Date | Feb. 3, 2022, 4 p.m. |
| Last Update | Nov. 21, 2024, 3:09 p.m. |
| CVSS3.1 : HIGH | |
| スコア | 8.2 |
|---|---|
| Vector | CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
| 攻撃元区分(AV) | ローカル |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 高 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更あり |
| 機密性への影響(C) | 高 |
| 完全性への影響(I) | 高 |
| 可用性への影響(A) | 高 |
| CVSS2.0 : HIGH | |
| Score | 7.2 |
|---|---|
| Vector | AV:L/AC:L/Au:N/C:C/I:C/A:C |
| 攻撃元区分(AV) | ローカル |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | 高 |
| 完全性への影響(I) | 高 |
| 可用性への影響(A) | 高 |
| Get all privileges. | いいえ |
| Get user privileges | いいえ |
| Get other privileges | いいえ |
| User operation required | いいえ |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:* | 5.0 | 5.08.29 | |||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:* | 5.1 | 5.16.29 | |||
| Configuration3 | or higher | or less | more than | less than | |
| cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:* | 5.2 | 5.26.29 | |||
| Configuration4 | or higher | or less | more than | less than | |
| cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:* | 5.3 | 5.35.29 | |||
| Configuration5 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:* | ||||
| Configuration6 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:* | ||||
| Configuration7 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:* | ||||
| Configuration8 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:* | ||||
| Configuration9 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:* | ||||
| Configuration10 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:* | ||||
| Configuration11 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:* | ||||
| Configuration12 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:* | ||||
| Configuration13 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:* | ||||
| Configuration14 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:* | ||||
| Configuration15 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:* | ||||
| Configuration16 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:* | ||||
| Configuration17 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:* | ||||
| Configuration18 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:* | ||||
| Title | Insyde InsydeH2O におけるバッファエラーの脆弱性 |
|---|---|
| Summary | Insyde InsydeH2O には、バッファエラーの脆弱性が存在します。 |
| Possible impacts | 情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution | ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date | Feb. 1, 2022, midnight |
| Registration Date | Feb. 17, 2022, 10:51 a.m. |
| Last Update | Feb. 28, 2022, 4:09 p.m. |
| Insyde Software |
| InsydeH2O |
| No | Changed Details | Date of change |
|---|---|---|
| 1 | [2022年02月17日] 掲載 |
Feb. 17, 2022, 10:51 a.m. |
| 2 | [2022年02月28日] 参考情報:JVN (JVNVU#98748974) を追加 |
Feb. 28, 2022, 2:14 p.m. |