260731
|
- |
|
apache
|
traffic_server
|
Apache Traffic Server 2.0.x and 3.0.x before 3.0.4 and 3.1.x before 3.1.3 does not properly allocate heap memory, which allows remote attackers to cause a denial of service (daemon crash) via a long …
|
CWE-119
Incorrect Access of Indexable Resource ('Range Error')
|
CVE-2012-0256
|
2013-03-26 12:31 |
2012-03-26 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260732
|
- |
|
cisco
|
prime_central_for_hosted_collaboration_solution_assurance
|
Cisco Prime Central for Hosted Collaboration Solution (HCS) Assurance 8.6 and 9.0 allows remote attackers to cause a denial of service (CPU consumption and monitoring outage) via malformed TLS messag…
|
CWE-20
Improper Input Validation
|
CVE-2013-1135
|
2013-03-23 12:15 |
2013-02-28 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260733
|
- |
|
apple
|
iphone_os
|
The kernel in Apple iOS before 6 dereferences invalid pointers during the handling of packet-filter data structures, which allows local users to gain privileges via a crafted program that makes packe…
|
CWE-264
Permissions, Privileges, and Access Controls
|
CVE-2012-3728
|
2013-03-23 12:12 |
2012-09-21 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260734
|
- |
|
cisco
|
nx-os nexus_7000 nexus_7000_10-slot nexus_7000_18-slot nexus_7000_9-slot
|
Cisco NX-OS 4.2, 5.0, 5.1, and 5.2 on Nexus 7000 series switches, when the High Availability (HA) policy is configured for Reset, allows remote attackers to cause a denial of service (device reset) v…
|
NVD-CWE-noinfo
|
CVE-2012-2469
|
2013-03-23 12:10 |
2012-08-7 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260735
|
- |
|
siemens
|
simatic_pcs7 wincc
|
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files v…
|
CWE-22
Path Traversal
|
CVE-2013-0679
|
2013-03-22 23:25 |
2013-03-22 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260736
|
- |
|
siemens
|
simatic_pcs7 wincc
|
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a craft…
|
CWE-200
Information Exposure
|
CVE-2013-0677
|
2013-03-22 23:11 |
2013-03-22 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260737
|
- |
|
siemens
|
simatic_pcs7 wincc
|
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote auth…
|
CWE-264
Permissions, Privileges, and Access Controls
|
CVE-2013-0676
|
2013-03-22 22:55 |
2013-03-22 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260738
|
- |
|
siemens
|
simatic_pcs7 wincc
|
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a deni…
|
CWE-119
Incorrect Access of Indexable Resource ('Range Error')
|
CVE-2013-0675
|
2013-03-22 22:52 |
2013-03-22 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260739
|
- |
|
siemens
|
simatic_pcs7 wincc
|
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long p…
|
CWE-119
Incorrect Access of Indexable Resource ('Range Error')
|
CVE-2013-0674
|
2013-03-22 22:49 |
2013-03-22 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
260740
|
- |
|
siemens
|
wincc_tia_portal
|
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
|
CWE-79
Cross-site Scripting
|
CVE-2013-0667
|
2013-03-22 22:38 |
2013-03-21 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|