212641
|
8.3 |
HIGH
Network
|
schneider-electric
|
wiser_for_knx_firmware spacelynk_firmware
|
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control w…
|
CWE-287
Improper Authentication
|
CVE-2019-6832
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212642
|
6.5 |
MEDIUM
Network
|
schneider-electric
|
hmigto_firmware hmisto_firmware xbtgh_firmware hmigtu_firmware hmiscu_firmware hmistu_firmware xbtgt_firmware hmigxo_firmware hmigxu_firmware
|
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HM…
|
CWE-754
Improper Check for Unusual or Exceptional Conditions
|
CVE-2019-6833
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212643
|
8.6 |
HIGH
Network
|
schneider-electric
|
bmxnor0200h_firmware
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active con…
|
CWE-754
Improper Check for Unusual or Exceptional Conditions
|
CVE-2019-6831
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212644
|
5.9 |
MEDIUM
Network
|
schneider-electric
|
modicon_m580_firmware
|
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the …
|
CWE-755
Improper Handling of Exceptional Conditions
|
CVE-2019-6830
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212645
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_m580_firmware modicon_m340_firmware
|
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service…
|
CWE-755
Improper Handling of Exceptional Conditions
|
CVE-2019-6829
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212646
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_m580_firmware modicon_m340_firmware modicon_premium_firmware modicon_quantum_firmware
|
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum …
|
CWE-755
Improper Handling of Exceptional Conditions
|
CVE-2019-6828
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212647
|
7.8 |
HIGH
Local
|
schneider-electric
|
somachine_hvac
|
A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious D…
|
CWE-426
Untrusted Search Path
|
CVE-2019-6826
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212648
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_m340_firmware bmxnor0200h_firmware
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware vers…
|
CWE-754
Improper Check for Unusual or Exceptional Conditions
|
CVE-2019-6813
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212649
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_quantum_140noe77101_firmware modicon_quantum_140noe77111_firmware
|
An Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability exists in Modicon Quantum 140 NOE771x1 version 6.9 and earlier, which could cause denial of service when the module rec…
|
CWE-754
Improper Check for Unusual or Exceptional Conditions
|
CVE-2019-6811
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
212650
|
8.8 |
HIGH
Network
|
schneider-electric
|
bmxnor0200h_firmware
|
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using…
|
NVD-CWE-Other
|
CVE-2019-6810
|
2024-11-21 13:47 |
2019-09-18 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|