213191
|
9.8 |
CRITICAL
Network
|
adobe
|
xd
|
Adobe XD versions 16.0 and earlier have a path traversal vulnerability. Successful exploitation could lead to arbitrary code execution.
|
CWE-22
Path Traversal
|
CVE-2019-7105
|
2024-11-21 13:47 |
2019-05-24 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213192
|
9.8 |
CRITICAL
Network
|
adobe
|
shockwave_player
|
Adobe Shockwave Player versions 12.3.4.204 and earlier have a memory corruption vulnerability. Successful exploitation could lead to arbitrary code execution.
|
CWE-787
Out-of-bounds Write
|
CVE-2019-7104
|
2024-11-21 13:47 |
2019-05-24 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213193
|
7.5 |
HIGH
Network
|
adobe
|
dreamweaver
|
Adobe Dreamweaver versions 19.0 and earlier have an insecure protocol implementation vulnerability. Successful exploitation could lead to sensitive data disclosure if smb request is subject to a rela…
|
NVD-CWE-noinfo
|
CVE-2019-7097
|
2024-11-21 13:47 |
2019-05-24 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213194
|
9.8 |
CRITICAL
Network
|
schneider-electric
|
modicon_premium_firmware modicon_quantum_firmware modicon_m340_firmware modicon_m580_firmware
|
A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwritin…
|
CWE-306
Missing Authentication for Critical Function
|
CVE-2019-6808
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213195
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_premium_firmware modicon_quantum_firmware modicon_m340_firmware modicon_m580_firmware
|
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing …
|
CWE-755
Improper Handling of Exceptional Conditions
|
CVE-2019-6807
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213196
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_premium_firmware modicon_quantum_firmware modicon_m340_firmware modicon_m580_firmware
|
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when …
|
NVD-CWE-noinfo
|
CVE-2019-6806
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213197
|
6.5 |
MEDIUM
Network
|
schneider-electric
|
modicon_m580_firmware modicon_m340_firmware modicon_quantum_firmware modicon_premium_firmware
|
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, a…
|
CWE-330
Use of Insufficiently Random Values
|
CVE-2019-6821
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213198
|
8.2 |
HIGH
Network
|
schneider-electric
|
modicon_m100_firmware modicon_m200_firmware modicon_m221_firmware atv_imc_drive_controller_firmware modicon_m241_firmware modicon_m251_firmware modicon_m258_firmware modicon_lmc0…
|
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a speci…
|
CWE-306
Missing Authentication for Critical Function
|
CVE-2019-6820
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213199
|
7.5 |
HIGH
Network
|
schneider-electric
|
modicon_m340_firmware modicon_m580_firmware modicon_quantum_firmware modicon_premium_firmware
|
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists which could cause a possible Denial of Service when specific Modbus frames are sent to the controller in the produ…
|
CWE-754
Improper Check for Unusual or Exceptional Conditions
|
CVE-2019-6819
|
2024-11-21 13:47 |
2019-05-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
213200
|
9.1 |
CRITICAL
Network
|
schneider-electric
|
modicon_quantum_firmware
|
In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol.
|