210481
|
7.5 |
HIGH
Network
|
siemens
|
simatic_mv440_sr_firmware simatic_mv440_hr_firmware simatic_mv440_ur_firmware simatic_mv420_sr-b_firmware simatic_mv420_sr-p_firmware simatic_mv420_sr-b_body_firmware simatic_mv420_…
|
A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP…
|
CWE-129
Improper Validation of Array Index
|
CVE-2020-25241
|
2024-11-21 14:17 |
2021-03-16 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210482
|
8.8 |
HIGH
Network
|
siemens
|
sinema_remote_connect_server
|
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integr…
|
-
|
CVE-2020-25240
|
2024-11-21 14:17 |
2021-03-16 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210483
|
8.8 |
HIGH
Network
|
siemens
|
sinema_remote_connect_server
|
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the…
|
-
|
CVE-2020-25239
|
2024-11-21 14:17 |
2021-03-16 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210484
|
5.5 |
MEDIUM
Local
|
siemens
|
logo\!_8_bm_firmware
|
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO!…
|
-
|
CVE-2020-25236
|
2024-11-21 14:17 |
2021-03-16 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210485
|
8.8 |
HIGH
Network
|
advantech
|
webaccess\/scada
|
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an adminis…
|
CWE-610
Externally Controlled Reference to a Resource in Another Sphere
|
CVE-2020-25161
|
2024-11-21 14:17 |
2021-02-24 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210486
|
7.8 |
HIGH
Local
|
fujielectric
|
v-server
|
The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
|
CWE-787
Out-of-bounds Write
|
CVE-2020-25171
|
2024-11-21 14:17 |
2021-02-20 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210487
|
5.5 |
MEDIUM
Local
|
nfstream
|
nfstream
|
An issue was discovered in NFStream 5.2.0. Because some allocated modules are not correctly freed, if the nfstream object is directly destroyed without being used after it is created, it will cause a…
|
CWE-401
Missing Release of Memory after Effective Lifetime
|
CVE-2020-25340
|
2024-11-21 14:17 |
2021-02-17 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210488
|
7.8 |
HIGH
Local
|
siemens
|
digsi_4
|
A vulnerability has been identified in DIGSI 4 (All versions < V4.94 SP1 HF 1). Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an a…
|
-
|
CVE-2020-25245
|
2024-11-21 14:17 |
2021-02-10 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210489
|
7.8 |
HIGH
Local
|
siemens
|
totally_integrated_automation_portal simatic_process_control_system_neo
|
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local atta…
|
CWE-427
Uncontrolled Search Path Element
|
CVE-2020-25238
|
2024-11-21 14:17 |
2021-02-10 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
210490
|
8.1 |
HIGH
Network
|
siemens
|
sinec_network_management_system sinema_server
|
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1 Update 1), SINEMA Server (All versions < V14.0 SP2 Update 2). When uploading files to an affected system using a zip containe…
|
-
|
CVE-2020-25237
|
2024-11-21 14:17 |
2021-02-10 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|