194991
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation o…
|
-
|
CVE-2021-22758
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194992
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity ch…
|
-
|
CVE-2021-22757
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194993
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supp…
|
CWE-125
Out-of-bounds Read
|
CVE-2021-22756
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194994
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity c…
|
-
|
CVE-2021-22755
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194995
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of …
|
-
|
CVE-2021-22754
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194996
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a …
|
-
|
CVE-2021-22753
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194997
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a m…
|
-
|
CVE-2021-22752
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194998
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of in…
|
-
|
CVE-2021-22751
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
194999
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a…
|
-
|
CVE-2021-22750
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
195000
|
5.3 |
MEDIUM
Network
|
schneider-electric
|
modicon_x80_bmxnor0200h_rtu_firmware
|
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the curren…
|
-
|
CVE-2021-22749
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|