|
196321
|
9.8 |
CRITICAL
Network
|
schneider-electric
|
powerlogic_egx100_firmware powerlogic_egx300_firmware
|
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code executi…
|
CWE-20
Improper Input Validation
|
CVE-2021-22765
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196322
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malic…
|
CWE-22
Path Traversal
|
CVE-2021-22762
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196323
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of informat…
|
-
|
CVE-2021-22761
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196324
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing c…
|
-
|
CVE-2021-22760
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196325
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when …
|
-
|
CVE-2021-22759
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196326
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation o…
|
-
|
CVE-2021-22758
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196327
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity ch…
|
-
|
CVE-2021-22757
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196328
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supp…
|
CWE-125
Out-of-bounds Read
|
CVE-2021-22756
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196329
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity c…
|
-
|
CVE-2021-22755
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
196330
|
7.8 |
HIGH
Local
|
schneider-electric
|
interactive_graphical_scada_system
|
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of …
|
-
|
CVE-2021-22754
|
2024-11-21 14:50 |
2021-06-12 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|